4.5 Article

Isolated patellofemoral arthroplasty reproduces natural patellofemoral joint kinematics when the patella is resurfaced

期刊

KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY
卷 24, 期 11, 页码 3668-3677

出版社

SPRINGER
DOI: 10.1007/s00167-014-3415-5

关键词

Patellofemoral arthroplasty; Kinematics; Contact pressure; Patellar resurfacing

向作者/读者索取更多资源

The objectives of this in vitro project were to compare the dynamic three-dimensional patellofemoral kinematics, contact forces, contact areas and contact pressures of a contemporary patellofemoral prosthetic implant with those of the native knee and to measure the influence of patellar resurfacing and patellar thickness. The hypothesis was that these designs are capable to reproduce the natural kinematics but result in higher contact pressures. Six fresh-frozen specimens were tested on a custom-made mechanical knee rig before and after prosthetic trochlear resurfacing, without and with patellar resurfacing in three different patellar thicknesses. Full three-dimensional kinematics were analysed during three different motor tasks, using infrared motion capture cameras and retroflective markers. Patellar contact characteristics were registered using a pressure measuring device. The patellofemoral kinematic behaviour of the patellofemoral arthroplasty was similar to that of the normal knee when the patella was resurfaced, showing only significant (p < 0.0001) changes in patellar flexion. Without patellar resurfacing, significant more patellar flexion, lateral tilt and lateral rotation was noticed. Compared to the normal knee, contact pressures were significantly elevated after isolated trochlear resurfacing. However, the values were more than doubled after patellar resurfacing. Changes in patellar thickness only influenced the antero-posterior patellar position. There was no other influence on the kinematics, and only a limited influence on the contact pressures in the low flexion angles. The investigated design reproduced the normal patellofemoral kinematics acceptable well when the patella was resurfaced. From a kinematic point of view, patellar resurfacing may be advisable. However, the substantially elevated patellar contact pressures remain a point of concern in the decision whether or not to resurface the patella. This study therefore not only adds a new point in the discussion whether or not to resurface the patella, but also supports the claimed advantage that a patellofemoral arthroplasty is capable to reproduce the natural knee kinematics.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.5
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据