4.6 Article

KTP Laser Nerve Sparing Radical Prostatectomy: Comparison of Ultrasonic and Cold Scissor Dissection on Cavernous Nerve Function

期刊

JOURNAL OF UROLOGY
卷 181, 期 6, 页码 2760-2766

出版社

ELSEVIER SCIENCE INC
DOI: 10.1016/j.juro.2009.01.095

关键词

prostate; lasers, solid-state; nerve tissue; prostatectomy

资金

  1. Laser-scope

向作者/读者索取更多资源

Purpose: Energy sources used during nerve sparing radical prostatectomy are known to compromise cavernous nerve function. Lasers offer the potential for accurate dissection while minimizing collateral injury to delicate neural structures. We evaluated cavernous nerve function following KTP laser dissection and compared outcomes to those of ultrasonic shears and cold scissor dissection. Materials and Methods: Laparoscopic unilateral neurovascular bundle mobilization was performed in 36 survival dogs using a KTP laser, ultrasonic shears and an athermal technique with cold scissors and clips in 12 each. Peak intracavernous pressure upon cavernous nerve stimulation, expressed as a percent of mean arterial pressure, was measured acutely and at 1 month. Thermal spread from the KTP laser and ultrasonic shears was assessed histologically ex vivo in harvested peritoneum. Results: Median peak intracavernous pressure as a percent of mean arterial pressure was similar immediately and 1 month after laser and athermal dissection, and significantly decreased after dissection with ultrasonic shears. Acute peak intracavernous pressure as a percent of mean arterial pressure was 53%, 96% and 98% for ultrasonic shears, laser and the athermal technique, respectively (laser vs athermal p = 0.51, ultrasonic shears vs laser p < 0.001 and ultrasonic shears vs athermal p < 0.001). Chronic peak intracavernous pressure as a percent of mean arterial pressure was 56%, 98% and 100% for ultrasonic shears, laser and the athermal technique, respectively (laser vs athermal p = 0.38, ultrasonic shears vs laser p = 0.016 and ultrasonic shears vs athermal p = 0.013). The median depth of acute laser injury was 600 mu m compared to 1.2 mm for ultrasonic shear dissection and 450 mu m crush injury due to the athermal technique. Thermography revealed less collateral thermal spread from the laser than from the ultrasonic shears (median greater than 60C thermal spread 1.07 vs 6.42 mm, p < 0.01). Conclusions: The KTP laser was comparable to the athermal technique and superior to the ultrasonic shears for preserving cavernous nerve function.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据