期刊
JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS
卷 12, 期 -, 页码 139-143出版社
ELSEVIER SCIENCE BV
DOI: 10.1016/j.jmbbm.2012.01.018
关键词
Adhesive systems; Polymerization; Light-curing unit; Degree of conversion; Mechanical properties
资金
- Fundacao de Amparo a Pesquisa do Estado de Sao Paulo - FAPESP [2009/03763-0, 2009/15589-4]
- Conselho Nacional de Pesquisa e Desenvolvimento - PQ/CNPq [304076/2009-0]
- Fundacao de Amparo a Pesquisa do Estado de Sao Paulo (FAPESP) [09/15589-4] Funding Source: FAPESP
The aim of the present study was to evaluate the degree of conversion (DC), elastic modulus (E), and flexural strength (FS) of five adhesive systems (only the bonding component of both Scotchbond MP-SBMP and Clearfil Protect Bond-CP; Single Bond 2-SB2; One-up Bond F Plus-OUP; and P90 System Adhesive: primer-P90P and bond-P90B) cured with a quartz tungsten halogen (QTH) lamp and a light-emitting diode (LED). Two groups per adhesive were formed (n = 5), according to the light source (quartz tungsten halogen - QTH: Demetron LC; and light-emitting diode - LED: UltraLume 5). Bar-shaped specimens were evaluated using three-point bending. The DC was obtained by Fourier transform infrared spectroscopy (FTIR). SB2 and P90P exhibited better DC values for QTH curing. However, SB2 and P90P presented the worst results overall. The light source was statistically significant for all adhesives, except for P90B and OUP. Non-solvated adhesives presented the best E and FS values. It could be concluded that the DC and E values can be influenced by the light source; however, this interference is material dependent. (C) 2012 Elsevier Ltd. All rights reserved.
作者
我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。
推荐
暂无数据