期刊
JOURNAL OF SPORTS SCIENCES
卷 30, 期 12, 页码 1303-1310出版社
TAYLOR & FRANCIS LTD
DOI: 10.1080/02640414.2012.709266
关键词
body site; motion sensor; intensity thresholds; participant compliance; Actiwatch
This study examined dissonance in physical activity (PA) between two youth-specific hip-derived intensity cut-points for the Actiwatch (AW), and compared PA between hip and wrist placements using site-specific cut-points. Twenty-four children aged 11.2 +/- 0.5 years wore the AW on the right hip and non-dominant wrist during a typical school day. Minutes of sedentary behaviour and vigorous activity were greater using Puyau et al. (2002) cut-points, but light, moderate, and moderate-to-vigorous (MVPA) were greater when derived using Puyau et al. (2004) cut-points (P<0.01). Total hip activity counts were lower than wrist. Sedentary minutes were greater at the hip, but minutes of light, vigorous and MVPA were lower (P<0.01). Moderate minutes were greater at the hip, but differed only when applying the Puyau et al. (2004) cut-points (P<0.01). In conclusion, data comparisons between two hip derived AW cut-points and between hip and wrist data are inappropriate. Future researchers using the AW at the hip should present data reduced using both published cut-points. As hip and wrist data differ, the wrist placement is preferable as it will likely increase children's compliance to monitoring protocols due to reduced obtrusiveness compared to the hip.
作者
我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。
推荐