4.1 Article

Evaluation of the Application of Computer-Aided Shape-Adapted Fabricated Titanium Mesh for Mirroring-Reconstructing Orbital Walls in Cases of Late Post-Traumatic Enophthalmos

期刊

JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY
卷 68, 期 9, 页码 2070-2075

出版社

W B SAUNDERS CO-ELSEVIER INC
DOI: 10.1016/j.joms.2009.08.029

关键词

-

资金

  1. Beijing Municipal Development Foundation [2007-3008]

向作者/读者索取更多资源

Purpose: Computer-aided individually shape-adapted fabricated titanium mesh for the mirroring-reconstruction of the orbit is a promising method for the correction of post-traumatic enophthalmos. The purpose of this study was to evaluate the application of this technique and assess the treatment outcomes. Patients and Methods: Twenty-one patients with delayed treatment of unilateral impure orbital fracture and post-traumatic enophthalmos were included in this study. Computed tomography-based mirroring-reconstruction images of the orbit were obtained for each individual to fabricate anatomically adaptive titanium mesh by computer-aided design and computer-aided manufacturing techniques. After exposing the areas of orbital defect and reducing the herniated soft tissue, the titanium mesh was inserted to reconstruct the internal orbit with a mean deep extension of 29.33 mm. Measurements were performed to assess the change in the degree of enophthalmos and orbital volume before and after surgery. Paired samples t test and Pearson correlation coefficient were employed for statistical analysis. Results: Follow-up examinations revealed that the degree of enophthalmos decreased to less than 2 mm in 11 patients, 2 to 4 mm in 9 patients, and remained greater than 7 mm in 1 patient. Statistical analysis revealed that post-traumatic enophthalmos in this series was 4.05 +/- 2.02 mm, which was associated with an orbital volume increment of 6.61 +/- 3.63 cm(3), with a regression formula of enophthalmos = 0.446 X orbital volume increment + 2.406. Orbital reconstruction effected a orbital volume decrease of 4.24 +/- 2.41 cm(3) and enophthalmos correction of 2.01 +/- 1.46 mm, the regression formula being enophthalmos = 0.586 X orbital volume decrease + 0.508. After surgery, the degree of unresolved enophthalmos was 2.03 +/- 1.52 mm, and the retained orbital volume expansion was 2.23 +/- 2.86 cm(3), and the regression formula was enophthalmos = 0.494 X orbital volume expansion + 1.415. Conclusion: Application of the individual fabricated titanium mesh for orbital reconstruction reduced the trauma-induced orbital volume increment by 65% and corrected 50% of severe late enophthalmos. Additional augmentation of orbital contents was required for further correction. The related treatment parameters were suggested. (C) 2010 American Association of Oral and Maxillofacial Surgeons J Oral Maxillofac Surg 68:2070-2075, 2010

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.1
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据