4.1 Article

Evaluation of the Performance of the N95-Companion: Effects of Filter Penetration and Comparison with Other Aerosol Instruments

期刊

出版社

TAYLOR & FRANCIS INC
DOI: 10.1080/15459624.2012.685838

关键词

face seal leakage; filter penetration; fit testing; N95-Companion; N95 filtering facepiece respirators; Porta-Count Plus

资金

  1. NIOSH [927 Z1NT]

向作者/读者索取更多资源

Fit factor is the ratio of the particle concentration outside (C-out) to the inside (C-in) of the respirator and assumes that filter penetration is negligible. For Class-95 respirators, concerns were raised that filter penetration could bias fit test measurements. The TSI N95-Companion was designed to overcome this limitation by measuring only 40-60 nm size particles. Recent research has shown that particles in this size range are the most penetrating for respirators containing electrostic filter media. The goal of this study was to better understand the performance of the N95-Companion by assessing the impact of filter penetration and by comparing C-out/C-in ratios measured by other aerosol instruments (nano-Differential Mobility Analyzer/Ultrafine Condensation Particle Counter (nano-DMA/UCPC) and the TSI PortaCount Plus) using N95 filtering facepiece respirators sealed to a manikin and with intentionally created leaks. Results confirmed that 40-60 nm-diameter size room air particles were most penetrating for the respirators tested. A nonlinear relationship was found between the N95-Companion-measured C-out/C-in ratios and the other instruments at the sealed condition and at the small leak sizes because the N95-Companion measures only charged particles that are preferentially captured by the electrostic filter media, while the other instrument configurations also measure uncharged particles, which are captured less efficiently. The C-out/C-in ratios from the N95-Companion for experiments conducted under sealed condition suggest that filter penetration of negatively charged 40-60 nm size particles was less than 0.05%. Thus, the N95-Companion measured C-out/C-in ratios are due primarily to particle penetration through leakage, not through filter media, while the C-out/C-in ratios for the PortaCount, nano-DMA/UCPC, and UCPC result from a combination of face seal leakage and filter penetration.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.1
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据