Dead-end ultrafiltration concentration and IMS/ATP-bioluminescence detection of Escherichia coli O157:H7 in recreational water and produce wash

期刊

JOURNAL OF MICROBIOLOGICAL METHODS
卷 87, 期 3, 页码 338-342

出版社

ELSEVIER
DOI: 10.1016/j.mimet.2011.09.010

关键词

ATP bioluminescence; IMS; E. coli O157:H7; Produce; Recreational water; Ultrafiltration

资金

  1. U.S. Army Research, Development, and Engineering Command

向作者/读者索取更多资源

The purpose of this study was to develop a detection method for viable E. coli O157:H7 in fresh produce and recreational water. The method was evaluated using eight samples of produce wash and recreational water with or without spiked E. coli O157:H7 at <= 10(2) CFU . ml(-1) and concentrated using dead-end ultrafiltration (DEUF) to produce primary and secondary retentates. Fifty-four matrix replicates of undiluted secondary retentates or dilutions (1:2 or 1:10 in buffer) were evaluated using an IMS/ATP bioluminescence assay (IMS/ATP). Combining primary and secondary DEUF yielded a 2-4 log(10) increase in E. coli O157:H7 concentrations in spiked samples and resulted in signal-to-noise ratios 2-219 fold higher than controls, depending on the sample type. DEUF increased the concentration of E. coli O157:H7 to within the detectable limits of IMS/ATP. The combined assay provided detection of viable E. coli O157:H7 in produce and recreational water. Accurate detection of microbial pathogens using DEUF and IMS/ATP could reduce disease outbreaks from contaminated water sources and food products. (C) 2011 Elsevier B.V. All rights reserved.