4.3 Article

Numerical simulation and experiments of magnetic flux leakage inspection in pipeline steel

期刊

出版社

KOREAN SOC MECHANICAL ENGINEERS
DOI: 10.1007/s12206-008-1005-5

关键词

Finite element method; Inspection; Magnetic flux leakage; Pipeline steel

资金

  1. JIN CHUAN Advance Research Program of Science and Technology
  2. Science Foundation for Young Teachers of University of Electronic Science and Technology of China

向作者/读者索取更多资源

The magnetic flux leakage (MFL) method is Currently the most commonly used pipeline inspection technique. In this paper, numerical simulation and experimental investigation on defect inspection in pipeline steel using MFL were carried Out. In theoretical analysis, typical three-dimensional (3D) detects were accurately modeled and detailed MFL signals in the test surface were calculated by 3D finite element method (FEM). To confirm the 3D FEM results, different artificial defects were made and the MFL experiments were performed. The experimental Study demonstrated that the results were agreement with the 3D FEM result. The results show that the 3D FEM is an effective analysis method for pipeline steel MFL inspection.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.3
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据