Comparison of Laboratory and Field Calibration of a Soil-Moisture Capacitance Probe for Various Soils

期刊

出版社

ASCE-AMER SOC CIVIL ENGINEERS
DOI: 10.1061/(ASCE)IR.1943-4774.0000418

关键词

Soil-moisture sensor calibration; EC-20; Middle Rio Grande; Field and laboratory calibration; Dielectric soil-moisture probe; Factory-equation accuracy; Low-cost capacitance sensor; Precision irrigation; Increasing water-use efficiency

资金

  1. New Mexico Interstate Stream Commission
  2. Endangered Species Act Collaborative Program

向作者/读者索取更多资源

Throughout the American west, irrigated agriculture has been targeted to increase water-use efficiency because of increased urban demands. Soil-moisture sensors offer a method to achieve efficiency improvements, but have found limited use primarily because of high cost and lack of soil-specific calibration equations. In this paper, the Decagon EC-20 soil-moisture sensor (a low-cost capacitance sensor) has been examined and a unique laboratory-calibration method has been developed. Field-and laboratory-calibration equations were developed for six soil types (sand, sandy loam, silt loam, loam, clay loam, and clay) in the Middle Rio Grande Valley for alfalfa and grass hay fields. The average absolute error in volumetric water content for field calibration was 0.430 m(3)/m(3), and 0.012 m(3)/m(3) for the laboratory calibration. The factory-calibration equation for the EC-20 was also evaluated and found to yield an average absolute error of 0.049 m(3)/m(3). In this study, it was found that the EC-20 is a reliable, cost-effective, and accurate sensor, and it is recommended that the laboratory-calibration method presented in this paper be used to obtain maximum accuracy. It is also recommended that the field calibration of the EC-20 soil-moisture sensor be foregone, as this type of calibration exhibits large error rates that are associated with colocation of samples, voids, organic residues, and root densities. Additionally, it was found that the field-calibration method was time-consuming, covered a small range of moisture content values, and was destructive to the area around installed sensors, which could lead to additional measurement errors. DOI: 10.1061/(ASCE)IR.1943-4774.0000418. (C) 2012 American Society of Civil Engineers.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.3
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据