4.2 Article

Multiplex measurement of proinflammatory cytokines in human serum: Comparison of the Meso Scale Discovery electrochemiluminescence assay and the Cytometric Bead Array

期刊

JOURNAL OF IMMUNOLOGICAL METHODS
卷 372, 期 1-2, 页码 71-77

出版社

ELSEVIER SCIENCE BV
DOI: 10.1016/j.jim.2011.06.033

关键词

Multiplex assay; Cytokine; Biomarker; Serum; HIV

资金

  1. HIV Prevention Trials Network (HPTN)
  2. National Institute of Allergy and Infectious Diseases (NIAID)
  3. National Institutes of Child Health and Human Development (NICH/HD)
  4. National Institute on Drug Abuse
  5. National Institute of Mental Health
  6. Office of AIDS Research, of the NIH, DHHS [1U01AI068613, UL1-RR025005, U01AI35042]
  7. NIH
  8. DHHS
  9. NIAID/University of Bamako HIV and Tuberculosis Research and Training Center in Mali

向作者/读者索取更多资源

Serum cytokine profiling is a powerful tool to link host immune defense with disease pathogenesis. Although several multiplex assays are commercially available, none has been rigorously validated in the context of chronic infectious disease (such as HIV infection). Here we compared the measurement of proinflammatory cytokines by two multiplex platforms: the Meso Scale Discovery (MSD) electrochemiluminescence assay and the Becton Dickinson Cytometric Bead Array (CBA) flow cytometric assay, using serum samples from HIV-infected and -uninfected donors. We evaluated the ability of these assays to: a) quantify circulating levels of native cytokines (IL-6, IL-8, IL-10, TNF-alpha, IL-12p70, IL-1 beta), and b) accurately recover known amounts of recombinant cytokines added to serum samples. Based on the standard curves, the sensitivity of the MSD system was only slightly better than the CBA. However, in serum the MSD platform consistently quantified levels of endogenous IL-12p70. TNF-alpha, and IL-10 that were undetectable by the CBA assay. The MSD assay was also more accurate as determined by an enhanced capacity to recover known concentrations of recombinant cytokines added to serum. Both assays performed equally well in quantifying IL-6 and IL-8, while neither assay quantified IL-1 beta with accuracy and precision. Interestingly, HIV infection did not affect the performance of either assay. Overall, the MSD assay provided a more reliable assessment of the proinflammatory cytokines tested in the serum of healthy and HIV-infected individuals. (C) 2011 Elsevier B.V. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.2
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据