4.7 Article

Degradation characteristics of secondary effluent of domestic wastewater by combined process of ozonation and biofiltration

期刊

JOURNAL OF HAZARDOUS MATERIALS
卷 150, 期 1, 页码 109-114

出版社

ELSEVIER SCIENCE BV
DOI: 10.1016/j.jhazmat.2007.04.092

关键词

ozonation; biofilter; advanced treatment; secondary effluent of domestic wastewater

向作者/读者索取更多资源

The performance of the combined process of ozonation and biofiltration was studied for treating the secondary effluent from sewage treatment plant. It was found that COD, NH3-N, and TOC were removed from 40-52,10-19, and 9-13 mg/L in the raw water to 18-23,0.5-1.5, and 7-8.5 mg/L in the effluent water (removal efficiency were 58, 89, and 25%, respectively), respectively, with an ozone dose of 10 mg/L (0.7-1.1 mg O-3/(mg TOC) and 0.2-0.25 mg O-3/(mg COD)), and contacting time of 4 min. Under the operation conditions, ozonation enhanced the biodegradability of the organics in the secondary effluent, as illustrated by increasing biodegradable dissolved organic carbon (BDOC) value from 0.8-1.1 mg/L in the raw water to the 2.0-2.7 mg/L in the effluent water. Meanwhile, the percentage of the organics with molecular size less than 1 k Da in the secondary effluent increased from 52.9 to 72.6%. The experimental results supported the expectation that the combined process of O-3/Biofiltration might enhance the overall treatment efficiency of secondary effluent treatment. (c) 2007 Elsevier B.V All rights reserved.