Development of rapid response thermocouple probes for use in a batch ohmic heating system

期刊

JOURNAL OF FOOD ENGINEERING
卷 93, 期 3, 页码 344-347

出版社

ELSEVIER SCI LTD
DOI: 10.1016/j.jfoodeng.2009.01.039

关键词

Ohmic heating; Temperature measurement; Thermocouple probe design

资金

  1. Non-Commnissioned Food Institutional Research Measure (FIRM)
  2. Irish Department of Agriculture, Fisheries and Food

向作者/读者索取更多资源

Temperature mapping during batch ohmic heating is a challenging but critically important task. It is essential to be able to monitor temperature changes at various, selected locations within a food to ensure a safe cooking process. Thermocouple probes of various designs and sizes were assembled and evaluated in order to develop thin, robust, fully insulated and rapid measurement devices. The response time of each probe was measured, and the accuracy and precision of the thermocouple probes were evaluated using established procedures. The most satisfactory thermocouple probe for application in a batch ohmic heating system was found to be a triple-point probe with a fully insulated stainless steel sheath having an outer diameter of 2 mm, an internal diameter of 1.5 mm and a response time of 0.6 s. (C) 2009 Elsevier Ltd. All rights reserved.