4.6 Article

Curing behaviour of high-viscosity bulk-fill composites

期刊

JOURNAL OF DENTISTRY
卷 42, 期 8, 页码 977-985

出版社

ELSEVIER SCI LTD
DOI: 10.1016/j.jdent.2014.05.012

关键词

Bulk-fill resin-based composites; Irradiance; Energy density; Hardness; Modulus of elasticity

向作者/读者索取更多资源

Objectives: This study aimed to assess the effect of curing conditions exposure time, mode, energy density, and exposure distance on the mechanical properties of high-viscosity bulk-fill resin-based composites (RBCs) measured at simulated clinical relevant filling depths. Methods: Three high-viscosity bulk-fill RBCs were investigated by assessing the variation in micromechanical properties in 200 m steps (Vickers hardness [HV] and, indentation modulus [El) within simulated 6-mm deep fillings (n = 5) polymerized under 16 different curing conditions. The exposure duration was 5, 20, and 40 s in the standard power mode; 3, 4, and 8 s in the high power mode; and 3 and 6 s in the plasma mode; the exposure distance was 0 and 7 mm. Energy density ranged from 2.63 to 47.03 J/cm(2). Measurements were performed after 24 h of storage in distilled water at 37 degrees C. The depth of cure (DOC) was calculated as the 80% hardness drop-off. Results: The results were compared using one- and multiple-way ANOVAs and Tukey's HSD post hoc test (alpha = 0.05). The effect of the parameter material was significant and strong on all measured properties (p < 0.05, partial eta-squared eta(2)(P), = 0.492 for E, 0.562 for HV, and 0.087 for DOC). Energy density exerted the strongest influence on the measured properties in all materials, whereas the influence of the exposure distance was strong on DOC, low on E and not significant on HV. The high-viscosity bulk-fill RBCs respond heterogeneously to variations in curing conditions. Conclusions: A lower energy density limit was identified, allowing for a 4 mm material bulk placement (5.88 J/cm(2) for EvoCeram Bulk Fill, 7.0 j/cm(2) for x-tra fil, and 23.51 J/cm(2) for SonicFill). This limit increased to 47.03 J/cm(2) for a 5 mm bulk placement, as claimed for SonicFill. To maintain mechanical properties in depth, however, an energy density of at least 23.51 J/cm(2) is recommended for EvoCeram Bulk Fill and x-tra fil and 47.03 J/cm(2) for SonicFill, respectively. This energy density should be achieved at moderate irradiance and increased curing time. Clinical significance: An exposure time of 20s at moderate irradiance is recommended for all materials for a 4 mm bulk placement. (C) 2014 Elsevier Ltd. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据