4.7 Article

Comparison of the Clinical Performance of PapilloCheck Human Papillomavirus Detection with That of the GP5+/6+-PCR-Enzyme Immunoassay in Population-Based Cervical Screening

期刊

JOURNAL OF CLINICAL MICROBIOLOGY
卷 48, 期 3, 页码 797-801

出版社

AMER SOC MICROBIOLOGY
DOI: 10.1128/JCM.01743-09

关键词

-

向作者/读者索取更多资源

We compared the clinical performance of the PapilloCheck human papillomavirus (HPV) assay with that of the GP5+/6+-PCR method with an enzyme immunoassay readout (GP5+/6+-PCR-EIA) for the detection of high-risk HPV (hrHPV) types by the use of cervical samples originating from women in a population-based by the use of cervical screening cohort tested by combined cytology and GP5+/6+-PCR-EIA (POBASCAM trial). Specimens from a random sample of 1,437 controls (women ages 40 to 60 years with normal cytological findings and without evidence of cervical intraepithelial neoplasia grade 2 or higher [>= CIN2] within up to 8 years of follow-up) and 192 cases (women ages 30 to 60 years in whom >= CIN3 was detected within up to 3 years of follow-up) were subjected to analysis by the PapilloCheck method. When all 17 (probably) hrHPV types were taken into account, the PapilloCheck assay had a clinical sensitivity for the detection of >= CIN3 of 96.4% (185/192 samples; 95% confidence interval [CI], 93.7 to 99.7) and a clinical specificity for the detection of >= CIN2 of 96.3% (95% CI, 95.3 to 97.3). After restriction of the analysis by the PapilloCheck assay to the 14 hrHPV types targeted by GP5+/6+-PCR-EIA, the clinical sensitivity and clinical specificity values were 95.8% (95% CI, 92.8 to 98.8) and 96.7% (95% CI, 95.7 to 97.7), respectively. By comparison, these values were 96.4% (95% CI, 93.9 to 98.9) and 97.7% (95% CI, 96.9 to 98.5), respectively, for the GP5+/6+-PCR-EIA. When all 17 (probably) hrHPV types were included in the analysis, noninferiority score testing revealed that the clinical sensitivity of the PapilloCheck assay for the detection of >= CIN3 was noninferior to that of the GP5+/6+-PCR-EIA (P < 0.0001), but the clinical specificity of the PapilloCheck assay for the detection of >= CIN2 was inferior to that of the GP5+/6+-PCR-EIA (P = 0.08) when lower bounds of 90% for sensitivity and 98% for specificity were used. When the analysis was restricted to the 14 hrHPV types targeted by the GP5+/6+-PCR-EIA, both the clinical sensitivity and the clinical specificity of the PapilloCheck assay were noninferior to those of the GP5+/6+-PCR-EIA (noninferiority score test; P < 0.0001 and P = 0.007, respectively). Thus, when the findings obtained for the 14 hrHPV types detectable by the GP5+/6+-PCR-EIA are considered, the PapilloCheck assay is clinically compatible with the GP5+/6+-PCR-EIA.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据