4.5 Article

Quantification of lactose content in human and cow's milk using UPLC-tandem mass spectrometry

出版社

ELSEVIER SCIENCE BV
DOI: 10.1016/j.jchromb.2011.09.053

关键词

LC-MS/MS; Carbohydrate; Lactose; Human milk; Cow's milk; Nutrition

向作者/读者索取更多资源

A sensitive, accurate, and specific quantitative UPLC-MS/MS method was developed for lactose measurement of cow's and human milk and validated with cow's milk samples certified by an external laboratory. The new method employs only a dilution of raw cow's and human milk for simple preparation with no need to remove protein and fat prior to analysis with UPLC-MS/MS. It was operated in negative mode to detect lactose molecules and labeled C-13(12)-lactose with the highest sensitivity. The principle advantages of the new LC-MS/MS method were: completed lactose determination in 5 min, absolute recovery of 97-107%, lower limit of detection <5 ng/L, and 99% linearity over the concentration range of 0.7-4.4 mg/L for both cow's and human milk. The mean lactose concentration of 51 human milk samples was measured as 56.8 5.5 g/L ranging from 43 to 65 g/L The described method represents validated lactose analysis with high accuracy and precision for a routine lactose determination in raw human milk. Crown Copyright (C) 2011 Published by Elsevier B.V. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.5
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文