4.6 Article

Impurity analysis of pure aldrin using heart-cut multi-dimensional gas chromatography mass spectrometry

期刊

JOURNAL OF CHROMATOGRAPHY A
卷 1277, 期 -, 页码 69-75

出版社

ELSEVIER
DOI: 10.1016/j.chroma.2012.12.038

关键词

Multi-dimensional GC/MS; Aldrin; Related-structure impurity analysis; Uncertainty evaluation; Persistent organic pollutant; Metrological research

资金

  1. 12th Five Years Major Project of Chinese National Programs for Scientific Instruments Research and Development [2011YQ 090005]
  2. National Natural Science Foundation of China [21005074, 21103032]

向作者/读者索取更多资源

Identification and quantification of related-structure impurity is a research focus in the purity assessment of organic compounds. Determination of the purity value and uncertainty assessment are also important in the metrological research. A method for the determination of related-structure impurity in pure aldrin sample has been developed by using heart-cut multi-dimensional gas chromatography-mass spectrometry (MDGC/MS). Compared to the traditional one-dimensional (1-D) GC system, the two separated columns in the MDGC/MS system can effectively reduce co-elution, enhance separation capability, and thus improve detectability of the trace-level impurities. In addition, MDGC/MS system was simultaneously equipped with flame ionization detector (FID) or electron capture detector (ECD) in the first GC unit and mass spectrometry (MS) detector in the second GC unit. Therefore, accurate quantitative results of the trace-level impurities can be easily achieved by isolation of principal component to the second dimension column using heart-cut process. The mass fraction of related-structure impurities in aldrin samples obtained using MDGC/MS system ranged from 6.8 x 10(-3) mg g(-1) to 26.47 mg g(-1) with five orders of magnitude, which is hard to be realized by mean of the 1-D GC. Excellent linearity with correlation coefficients of above 0.999 was achieved for each impurity analysis over a wide range of concentrations. Limits of quantification (LOQ) varied from 250 ng g(-1) to 330 ng g(-1) for FID, and from 1.0 ng g(-1) to 2.0 ng g(-1) detected by ECD. The combined standard uncertainty (u(c)) was lower than 0.37 mg g(-1) and 0.040 mg g(-1) detected using FID and ECD, respectively. Therefore, performance characterization of MDGC/MS used in the study is fit for quantification analysis of trace-level impurity. These results demonstrate that the MDGC/MS is extremely suitable for the purity assessment of organic compounds with medium structural complexity and low polarity. (C) 2013 Elsevier B.V. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据