4.6 Article

A new automatic mass detection method for breast cancer with false positive reduction

期刊

NEUROCOMPUTING
卷 152, 期 -, 页码 388-402

出版社

ELSEVIER
DOI: 10.1016/j.neucom.2014.10.040

关键词

Mass detection; Breast cancer; Level set; Local binary pattern; Support vector machine

资金

  1. Natural Science Foundation of China [61403287, 61273303, 31201121]
  2. Program for Changjiang Scholars and Innovative Research Team in University of China [IRT1245]
  3. Educational Commission of Hubei Province [D20131101]

向作者/读者索取更多资源

Mass localization is a crucial problem in computer-aided detection (CAD) system for the diagnosis of suspicious regions in mammograms. In this paper, a new automatic mass detection method for breast cancer in mammographic images is proposed. Firstly, suspicious regions are located with an adaptive region growing method, named multiple concentric layers (MCL) approach. Prior knowledge is utilized by tuning parameters with training data set during the MCL step. Then, the initial regions are further refined with narrow band based active contour (NBAC), which can improve the segmentation accuracy of masses, Texture features and geometry features are extracted from the regions of interest (ROI) containing the segmented suspicious regions and the boundaries of the segmentation. The texture features are computed from gray level co-occurrence matrix (GLCM) and completed local binary pattern (CLBP). Finally, the ROIs are classified by means of support vector machine (SVM), with supervision provided by the radiologist's diagnosis. To deal with the imbalance problem regarding the number of non-masses and masses, supersampling and downsampling are incorporated. The method was evaluated on a dataset with 429 craniocaudal (CC) view images, containing 504 masses. Among them, 219 images containing 260 masses are used to optimize the parameters during MCL step, and are used to train SVM. The remaining 210 images (with 244 masses) are used to test the performance. Masses are detected with 82.4% sensitivity with 5.3 false positives per image (FPsI) with MCL, and after active contour refinement, feature analysis and classification, it obtained 1.48 FPsI at the sensitivity 78.2%. Testing on 164 normal mammographic images showed 5.18 FPsI with MCL and 1.51 FPsI after classification. Experiments on mediolateral oblique (MLO) images have also been performed, the proposed method achieved a sensitivity 75.6% at 1.38 FPsI. The method is also analyzed with free response operating characteristic (FROC) and compared with previous methods. Overall, the proposed method is a promising approach to achieve low FPsI while maintaining a high sensitivity. (C) 2014 Elsevier B.V. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据