4.6 Article

Bone Ingrowth in Well-Fixed Retrieved Porous Tantalum Implants

期刊

JOURNAL OF ARTHROPLASTY
卷 28, 期 6, 页码 922-927

出版社

CHURCHILL LIVINGSTONE INC MEDICAL PUBLISHERS
DOI: 10.1016/j.arth.2013.01.035

关键词

aseptic loosening; bone ingrowth; porous tantalum components

资金

  1. National Institutes of Health (NIAMS) [R01 AR47904]
  2. Stryker Orthopaedics, Inc.
  3. Zimmer, Inc.
  4. Stelkast, Inc.
  5. Wilbert J. Austin Professor of Engineering Chair (CMR)

向作者/读者索取更多资源

While first generation porous coatings have had clinical success, aseptic loosening remains a leading cause of revision. The purpose of this study was to investigate the reasons for revision and to assess the amount of bone ingrowth in retrieved porous tantalum components. In a prospective multicenter retrieval program, 76 porous tantalum acetabular shells, 5 femoral stems, 7 patellas and 36 tibial trays were collected from revision surgeries. A subset of the implants was analyzed for bone ingrowth. The main reason for revision was infection for acetabular shells (1.4 yeah implantation time) and instability for tibial trays (1.8 years implantation time). Two of the thirty primary surgery acetabular shells and one of the thirty-six primary surgery tibial trays were revised for implant loosening. We observed full depth penetration of bone into the porous tantalum layer for the acetabular shells and femoral stems. (C) 2013 Elsevier Inc. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据