A systematic comparison of four bioaerosol generators: Affect on culturability and cell membrane integrity when aerosolizing Escherichia coli bacteria

期刊

JOURNAL OF AEROSOL SCIENCE
卷 70, 期 -, 页码 67-79

出版社

ELSEVIER SCI LTD
DOI: 10.1016/j.jaerosci.2014.01.002

关键词

Bioaerosol; Aerosolization; Aerosol generator; Cell damage; qPCR; Microorganism stress

资金

  1. Advanced Sampler for Measuring Exposure to Biological Aerosols (CDC/NIOSH) [R01-OH009783]
  2. New Jersey Agricultural Experiment Station (NJAES) at Rutgers, The State University of New Jersey

向作者/读者索取更多资源

Bioaerosol research requires stable and reliable aerosol generators that can produce high particle concentrations with minimal damage to microorganisms. This study compared Collison nebulizer, Liquid Sparging Aerosolizer (LSA), C-Flow nebulizer, and a newly designed Single-Pass Aerosolizer with respect to their physical performance, and ability to preserve the culturability and structural integrity of bacteria. Escherichia coli bacteria were aerosolized at different air pressures, collected by a BioSampler and their Cell Membrane Damage Index (I-D), expressed as the fraction of 16S rRNA gene copies in the supernatant liquid versus the amount of 16S rRNA gene copies in the total sample (cell pellet plus supernatant), was determined. The I-D of E. coli aerosolized by the Collison and C-Flow nebulizers at 40 psi compared to aerosolization at 5 and 15 psi was significantly higher (p<0.05). However, the I-D of E. coli aerosolized with the LSA and Single-Pass Aerosolizer did not seem to significantly depend on aerosolization pressure. The I-D of E. coli collected with a BioSampler was found to positively and significantly correlate (p=0.043) with the presence of airborne bacterial fragments (aerodynamic size range 0.37-0.523 pm) as measured by the Aerodynamic Particle Sizer. Increased loss of culturability was observed for bacteria aerosolized by the Collison nebulizer and Single-Pass Aerosolizer with increasing aerosolization pressure (p<0.05), while no significant change in culturability was found for the other two generators as a function of aerosolization pressure. At particle output concentration of similar to 100 particles/cm(3), the Single-Pass Aerosolizer preserved the culturability of bacteria significantly better than the other three generators (p<0.05). It also exhibited a significantly lower I-D (p<0.001) and less culturability reduction (p=0.03) compared to the Collison nebulizer at particle output concentrations of similar to 1000 particles/cm(3). It is hoped that this study will help bioaerosol researchers select a bioaerosol generator and method best suiting their studies. (C) 2014 Elsevier Ltd. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据