期刊
JAPANESE JOURNAL OF APPLIED PHYSICS
卷 47, 期 1, 页码 334-336出版社
JAPAN SOC APPLIED PHYSICS
DOI: 10.1143/JJAP.47.334
关键词
supercritical fluid; xenon; small path length; small-angle X-ray scattering; density fluctuation
We constructed a sample holder of Xe for small-angle X-ray scattering (SAXS) experiments. The holder was designed to attain a very small path length of a sample that corresponds to the large X-ray absorption of Xe. For the easy and convenient operation of the experiments in synchrotron radiation facilities, a cell was contrived so as to vary the path length despite the presence of a high-pressure sample inside. The path length varies from 0.05 to 3.5 mm. The holder is applicable not only to supercritical Xe but also to liquids, solutions and other supercritical fluids under highly pressured conditions using relatively low-energy X-rays. SAXS measurements were carried out for supercritical Xe in a wide density range. Density fluctuations for the fluid at various thermodynamic states were obtained from SAXS signals.
作者
我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。
推荐