4.5 Article

A voxel-based morphometry comparison of the 3.0T ADNI-1 and ADNI-2 volumetric MRI protocols

期刊

出版社

WILEY-BLACKWELL
DOI: 10.1002/gps.4179

关键词

ADNI-1; ADNI-2; MRI; grey matter (GM); white matter (WM); cerebral spinal fluid (CSF)

资金

  1. NIHR Biomedical Research Centre for Mental Health
  2. NIHR Biomedical Research Unit for Dementia at South London
  3. Maudsley NHS Foundation Trust
  4. Institute of Psychiatry
  5. King's College London
  6. Alzheimer Research UK
  7. European Medical Information Framework
  8. MRC [MR/J008915/1] Funding Source: UKRI
  9. Medical Research Council [MR/J008915/1] Funding Source: researchfish

向作者/读者索取更多资源

ObjectivesThe Alzheimer's Disease Neuroimaging Initiative 3.0T MRI image acquisition scheme changed between the original ADNI-1 grant and the two subsequent grants (ADNI-GO and ADNI-2). The aim of the current study was to investigate the compatibility of the 3.0T ADNI-1 and ADNI-2 T1-weighted volumes using voxel-based morphometry (VBM). MethodsT1-weighted images of 30 subjects were acquired using a 3T GE Signa HDx using the ADNI-1 and ADNI-2 T1-weighted volume sequences. Images were pre-processed and analysed using SPM8. Global grey matter (GM), white matter (WM) and cerebrospinal fluid (CSF) volumes were compared, as well as voxel-by-voxel differences in GM and WM. ResultsCorrelation coefficients and percentage differences for each tissue type between ADNI-1 and ADNI-2 were as follows: ((GM: intraclass correlation coefficient (ICC)=0.86, ADNI-1 3.09%ADNI-2) (CSF: ICC=0.90, ADNI-1 1.94%>ADNI-2)). For ADNI-2, widespread increases in GM were found relative to ADNI-1 (cerebellum and pre-central gyrus), with localised decreases along the midline and temporal lobes. For ADNI-1, widespread increases in WM were found relative to ADNI-2 (cerebellum and pre-central gyrus), together with localised decreases in the temporal gyrus. ConclusionsThe widespread increase in GM and localised decrease in WM in ADNI-2 compared to ADNI-1 images suggests that the image acquisition protocols are not directly comparable using SPM-8. Total volumes of GM, WM and CSF also differed between the protocols in the following order of magnitude: GM>WM>CSF. This has implications for studies aiming to analyse images acquired using the ADNI-1 and ADNI-2 protocols under VBM. (c) 2014 The Authors. International Journal of Geriatric Psychiatry published by John Wiley & Sons Ltd.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.5
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据