4.7 Article

Metrological comparison between Kinect I and Kinect II sensors

期刊

MEASUREMENT
卷 70, 期 -, 页码 21-26

出版社

ELSEVIER SCI LTD
DOI: 10.1016/j.measurement.2015.03.042

关键词

Standard artefact; Optical metrology; 3D sensing device; Gaming sensor; Precision; Accuracy

资金

  1. Xunta de Galicia [IPP055 - EXP44, EM2013/005, CN2012/269, R2014/032]
  2. Spanish Government [TIN2013-46801-C4-4-R, ENE2013-48015-C3-1-R, SICEMAM IPT-2012-1121-370000]

向作者/读者索取更多资源

This work shows a metrological comparison between Kinect I and Kinect II laser scanners. The comparison is made using a standard artefact based on 5 spheres and 7 cubes. Accuracy and precision tests are done for different ranges and changing the inclination angle between each sensor and the artefact. Results at 1 m range show similar precision in both cases with values between 2 mm and 6 mm. However, at 2 m range values of Kinect I increase up to 12 mm in some cases, while Kinect II keeps all results below 8 mm. Accuracy is also better for Kinect II at 1 m and 2 m range, with values always lower than -5 mm. Accuracy for Kinect I reaches -12 mm at 1 m range and -25 mm at 2 m range. Precision study shows a decrease of precision with range according a second order polynomial equation for Kinect I, while Kinect II shows a much more stable data. Measurement range of Kinect II is limited to 4 m, while Kinect I can obtain data up to 6 m. (C) 2015 Elsevier Ltd. All rights reserved.