4.4 Article Proceedings Paper

No-Insulation (NI) HTS Inserts for >1 GHz LTS/HTS NMR Magnets

出版社

IEEE-INST ELECTRICAL ELECTRONICS ENGINEERS INC
DOI: 10.1109/TASC.2011.2178976

关键词

Compact HTS insert magnet; GHz-class NMR; LTS/HTS NMR; no-insulation winding; self-protecting

资金

  1. NIBIB NIH HHS [R01 EB017097] Funding Source: Medline
  2. NIGMS NIH HHS [R01 GM137138] Funding Source: Medline

向作者/读者索取更多资源

A no-insulation (NI) technique has been applied to wind and test a NI HTS (YBCO) double-pancake coil at 4.2 K. Having little detrimental effect on field-current relationship, the absence of turn-to-turn insulation enabled the test coil to survive a quench at a coil current density of 1.58 kA/mm(2). The NIHTS coil is compact and self-protecting, two features suitable for large high-field magnets. To investigate beneficial impacts of the NI technique on >1 GHz LTS/HTS NMR magnets, we have designed six new NI HTS inserts for our ongoing 1.3 GHz LTS/HTS NMR magnet, which require less costly LTS background magnets than the original insulated HTS insert. A net result will be a significant reduction in the overall cost of an LTS/HTS NMR magnet, at 1.3 GHz and above.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.4
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据