IEEE SENSORS JOURNAL
卷 9, 期 12, 页码 1654-1659出版社
IEEE-INST ELECTRICAL ELECTRONICS ENGINEERS INC
DOI: 10.1109/JSEN.2009.2030388
关键词
Fiber Bragg grating (FBG); optical pressure sensor; pressure sensor
资金
- Petronas Research Services
A high sensitivity pressure sensor design without a polymer transducer is demonstrated in this paper. The sensor uses a thin metal diaphragm as a pressure transducer instead of a polymer. The sensor is tested to a maximum pressure of 100 psi and has a sensitivity of 0.0115 nm/psi, which matches the calculated sensitivity of 0.0127 nm/psi. The sensor is provides accurate measurement of the pressure and shows good repeatability in its readings. The sensor is also tested at the flow loop of the University of Tulsa, and shows a good match with the pressure readings of the flow loop.