期刊
HUMAN & EXPERIMENTAL TOXICOLOGY
卷 28, 期 6-7, 页码 353-359出版社
SAGE PUBLICATIONS LTD
DOI: 10.1177/0960327109105157
关键词
clothing; fibrous filters; filtration; gloves; nanoparticles
类别
In this study, different conventional personal protection devices ( fibrous filters, cartridges for respirators, protective clothing, and gloves) well qualified for micron particles were tested with graphite nanoparticles ranging from 10 to 100 nm ( electrical mobility diameter). For this purpose, two specific test benches were designed: one for filter-based devices which are tested under a controlled air flow and other for gloves and protective clothing based on the through diffusion method. The penetration versus particle size shows for most tested filter media the behavior predicted by the theoretical Brownian capture: penetration decreases when particle diameter decreases. No thermal rebound was detected until 10 nm for graphite nanoparticles. Protective clothes were tested by two methods and same trends were obtained. Nonwoven fabrics (air-tight materials) are much more efficient against nanoparticles than cotton and paper. Gloves tested by through diffusion technique, in static condition seem to efficiently protect against graphite nanoparticles in spite of their important porosity.
作者
我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。
推荐