4.6 Article

Effects of climatic test parameters on acetic acid emission from beech (Fagus sylvatica L.)

期刊

HOLZFORSCHUNG
卷 67, 期 1, 页码 47-51

出版社

WALTER DE GRUYTER GMBH
DOI: 10.1515/hf-2011-0237

关键词

acetic acid emission; beech; ion chromatography (IC); testing parameters of VOCs; thermal desorption-gas chromatography-mass spectrometry (TD-GC-MS)

资金

  1. Fachagentur fur Nachwachsende Rohstoffe (FNR e. V.)

向作者/读者索取更多资源

Acetic acid (AA) emission from beech samples was studied in test chambers operated according to ISO 16000 part 9 and as a function of temperature and relative humidity (RH). The impact of RH was higher than that of temperature. AA emission was about 45% higher at 75% RH than under standard parameters (50% RH, 23 degrees C). Probably, RH influences AA emission both by enhanced hydrolysis of acetyl groups, as well as by facilitating the release of AA into the surrounding air by diffusion. The concentration of AA in test chamber air was determined with thermal desorption-gas chromatographymass spectrometry (TD-GC-MS) as well as with ion chromatography (IC). Both techniques provided similar results. The values measured by IC ranged constantly 15% below those obtained with TD-GC-MS. This can be ascribed to losses during sampling of test chamber air.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据