96 次浏览 · 101 次下载 · ☆☆☆☆☆ 0.0

Exploring Possibilities and Drawbacks in the Analysis of Pb Loaded Reference Samples by Using TXRF Spectrometers

发表日期 September 28, 2022 (DOI: https://doi.org/10.54985/peeref.2209p6462368)

未经同行评议

作者

Paola Cirelli1 , Fabjola Bilo2 , Annalisa Zacco2 , Kouichi Tsuji3 , Tsugufumi Matsuyama3 , Giacomo Siviero4 , Luigi Pisani4 , Diane Eichert5 , Laura E. Depero6 , Laura Borgese2
  1. Department of Information Engineering, University of Brescia, via Branze 38, 25123 Brescia, Italy
  2. SMART SOLUTIONS s.r.l, via Corfù 106, 25124 Brescia, Italy
  3. Graduate School of Engineering, Osaka City University, Osaka, Japan
  4. GNR srl, via Torino 7, 28010, Agrate Conturbia (NO), Italy
  5. Elettra-Sincrotrone Trieste, Area Science Park, 34149 Basovizza, Trieste, Italy
  6. Department of Mechanical and Industrial Engineering, University of Brescia, via Branze 38, 25123 Bre

会议/活动

EXSA - VIRTUAL CONFERENCE IN X-RAY SPECTROMETRY, June 2021 (虚拟会议)

海报摘要

Particulate matter (PM) is a prominent air pollutant responsible for negative health effects. The determination of PM composition and concentration is important to assess the presence of potentially toxic elements. In this work we define a method for measurement and analysis of lead in PM filter samples, by measuring lead loaded reference samples plasticized with SMART STORE® using three total reflection X-ray fluorescence (TXRF) spectrometers. The sample preparation procedure consists in enclosing the filter between two polymeric foils, to avoid material losses, and to cut the sample in a disc of 30 mm diameter, equal to the dimension of the sample carrier. Reference samples are analysed, and from the detected fluorescence intensities calibration lines are built, applying both the analytical and the theoretical approach.

关键词

Environmental monitoring, Particulate matter, Air quality, TXRF, XRF

研究领域

Chemical Engineering, Environmental Engineering, Chemistry, Physics

参考文献

  1. Directive 2004/106/EC, Official Journal of the European Union, L 23/3
  2. L. Borgese, F. Bilo, A. Zacco, S. Federici, A. W. Mutahi, E. Bontempi, K. Trzepla, N. Hyslop, S. Yatkin, P. Wobrauschek, J. Prost, D. Ingerle, L. E. Depero, 2020, Spectrochimica Acta Part B 167, 105840

基金

  1. COST Action CA18130 ENFORCE TXRF

补充材料

暂无数据

附加信息

利益冲突
No competing interests were disclosed.
数据可用性声明
The datasets generated during and / or analyzed during the current study are available from the corresponding author on reasonable request.
知识共享许可协议
Copyright © 2022 Cirelli et al. This is an open access work distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
评分
引用
Cirelli, P., Bilo, F., Zacco, A., Tsuji, K., Matsuyama, T., Siviero, G., Pisani, L., Eichert, D., Depero, L., Borgese, L. Exploring Possibilities and Drawbacks in the Analysis of Pb Loaded Reference Samples by Using TXRF Spectrometers [not peer reviewed]. Peeref 2022 (poster).
复制引文

Discover Peeref hubs

Discuss science. Find collaborators. Network.

Join a conversation

Ask a Question. Answer a Question.

Quickly pose questions to the entire community. Debate answers and get clarity on the most important issues facing researchers.

Get Started